Anchorage Clamp with Screw-On Plate – Grade 100 – Cartec

Description

Anchorage Clamp with Screw-On Plate – Grade 100 – Cartec

Anchorage clamp with screw on plate for load lifting.

  • Safety Coefficient 4
  • Screw included in the package
  • Hex head screw burnished black cl 10.9 in compliance UNI5931/DIN912
  • The anchorage bracket may be used in total safety with a maximum of 20.000 lifting full loads.
  • Suitable for lifting in safety conditions in compliance to the machine directive 2006/42/EC
  • Painted with epoxy
  • Tested to 20.000 fatigue cycles

 

The eyebolt with the product code C825X is Grade 100.

 

SAFETY INSTRUCTIONS

FORESEEN USE

Bracket with screw-on plate used for lifting loads.

NOT SUITABLE FOR LIFTING PEOPLE

 

CE Conformity Declaration

(Machinery Directive 2006/42/EC all. IIA)

We declare that all materials specified in the present declaration are in compliance with all the dispositions related to the Directive 2006/42/EC

 

CHECK SUITABILITY OF ROTATING EYEBOLTS ART.800 BEFORE USE AND YEARLY

Before each use make sure that:

  • The eyebolt shows no defects due to wear, corrosion, cracks, or visible deformations.
  • Markings are clearly legible.
  • The loads to be lifted are in compliance with the rated capacities of the eyebolt (the working load limits are specified on the eyebolt and in the user manual).
  • The diameter of the welded ring has not been reduced by more than 10% of the nominal diameter due to wear at any contact point.
  • Once tightened, ensure the bulb rotates freely and properly.

If these checks give a negative outcome, the eyebolt must not be used any more, and must be replaced.

 

Please remember:

  • Inspections must be carried out by qualified personnel.
  • Checks have to be carried out by a qualified staff as the rotating eyebolts series 800 must undergo checks at regular intervals and scheduled in compliance with the laws in force
  • After an extended use of the anchorage bracket check fixing screws.
  • The rotating eyebolt with ring must only be installed and used by trained personnel of legal working age, following the Machinery Directive 2006/42/EC and its subsequent amendments.
  • The qualified person must supervise the lifting operation and must always detect the gravity center of the load and position the eyebolts in order to guarantee that the said load is always balanced
  • If the load is asymmetrical take into consideration a decrease of the capacity as shown on the reference chart
  • Check suitability of the resistance class of the mother screw which has to house the eyebolt with the ration of the load to be lifted (the material of the mother screw has to have traction resistance which is the same or higher than steel S235JR – norm of reference UNI EN 10025)
  • The depth of the threaded hole has to be minimum
    1*d for steel
    1.25*d for cast iron
    1.5*d for cast iron castings with low resistance (resistance <200 MPa)
    2*d for aluminum alloys
    2.5*d for aluminum – magnesium alloys
  • The threaded hole must be perpendicular to the surface
  • Make sure that the surface of the mother screw is suitable for the planarity and dimension in order to guarantee touching of all the surface place of the eyebolt and that it adheres suitably. The eyebolt cannot be used with parts of the tilting surface
  • To install: manually screw in the eyebolt using a wrench. Do not use extension bars or tools that can over-torque the bolt. Do not exceed the recommended torque in the chart.
  • Tighten the eyebolt until it is fully seated on the surface.
  • Orient the ring in the direction of the load.

 

CAPACITY REDUCTION FACTORS

Ambient Temperature Load Limit Reduction
• <-20°C Not permitted
• -20°C to +200°C None
• +200°C to +300°C -10%
• +300°C to +400°C -25%
• >+400°C Not permitted

  • Safety Coefficient 4
  • For lifting devices that remain attached to the structure we recommend the part being locked by means of thread brake glue
  • The eyebolt can be used safely up to maximum of 20.000 lifts with a full load
  • For risky lifting operations safety measures have to be taken for the people who undergo the risk
  • If the instructions are not adhered to serious damage can be caused to things and injuries to people
  • This documentation has been prepared in compliance with section 1.7.4.2 of the Machinery Directive 2006/42/EC.

If screws are used that are not provided by the supplier, they have to have suitable dimensions with respect to the bracket to which the screws are fixed to, class 12.9 and check the magnaflux with sampling at 100%.

 

NOT ALLOWED:

  • Do not use eyebolts in acid high corrosion chemical substance environment and/or in an explosive atmosphere
  • Η χρήση σε θερμοκρασίες εκτός του εύρους -20°C έως 400°C.
  • Do not exceed the capacity specified on the reference chart
  • Do not used for operations which defer from the ones that are foreseen
  • Do not use locking screws which are larger than the ones specified to assemble the eyebolt
  • No lifting is allowed with stress and rotation and or twisting under loading to the anchorage bracket.
  • Do not replace original screws
  • Do not use to life people
  • Do not stand under an overhanging load whilst it is being used
  • Do not stand during use in dangerous areas (dangerous areas means areas which are deemed risky due to falling of load during movement with accessories)
  • If changes, repairs and/or treatments are made to the product, the terms of the guarantee are no longer applicable and the manufacturer declines all liability.

 

STORAGE:

The device must be stored in a suitable environment (e.g. dry, non-corrosive, etc.)

 

 

 

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Anchorage Clamp with Screw-On Plate – Grade 100 – Cartec”

Your email address will not be published. Required fields are marked *

Category: